Device Telemetry and Analytics
You Can Only Analyse What Somebody
Chose to Measure, Years Ago
The Challenge
Adding a field means shipping firmware to a fleet
New instrumentation requires a firmware campaign
The schema was designed for diagnostics
Analysts were not in the design conversation
Generations carry different schemas
Data volume grows faster than analytical value
Definitions were never written down
Ask what question you could not answer last quarter, and why.
Our Approach
Put the analyst in the firmware design review
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Design retention as an option on future questions, covered on our device data engineering page.
Step 8
Step 9
Step 10
A field whose meaning nobody recorded is a field nobody can safely use.
Capabilities
Specify it, collect it, normalize it, use it
Specify
Telemetry Schema Design
Field Definition and Documentation
Schema Versioning
Sampling and Resolution Design
Collect and Normalize
Ingestion and Time-Series Engineering
Cross-Generation Normalization
Context Enrichment
Raw Preservation
Analyse
Utilization and Performance Analytics
Fault and Reliability Analytics
Fleet Cohort Comparison
Analytical Feasibility Assessment
What CaliberFocus does, and does not do?
Where It Applies?
Six questions, and the schema decides which you can answer
| Question | What It Informs | What the Schema Must Contain |
|---|---|---|
| Is the Device Faulting | Service response | Fault codes and error events. Almost always present, since this is why telemetry exists. |
| How Much Is It Being Used | Commercial, reliability and service planning | Operating cycles or duration. Frequently absent, and the highest-value gap. |
| Is Something Degrading | Preventive intervention | Continuous measurements at adequate resolution rather than threshold crossings. |
| Does This Configuration Perform Differently | Engineering and product decisions | Configuration carried with every measurement, which is often not the case. |
| What Happened Before the Failure | Investigation and root cause | Retained history at the time of the event, which retention policy may have discarded. |
Utilization Is the Field Nobody Instruments and Everybody Wants
ArchitectureÂ
Six decisions made on the device that bound everything after
| Decision | What It Governs | What Is Permanently Lost |
|---|---|---|
| Which Fields Exist | The entire analytical surface | Any question requiring an uninstrumented field, for that generation. |
| Sampling Rate | Whether short events are visible at all | Transients shorter than the interval, which never happened as far as data shows. |
| On-Device Aggregation | Whether raw values ever leave the device | Distribution and variance, where only an average is transmitted. |
| Buffer Depth | How much history survives an outage | Everything older than the buffer during a long disconnection. |
| Timestamp Source | Whether event sequence can be reconstructed | Reliable ordering, where the device clock drifts. |
| Transmission Trigger | When data arrives relative to when it happened | Timeliness, and the ability to act on anything in near real time. |
Prefer raw over aggregate where bandwidth allows
Instrument a usage counter even without a current question
Carry schema version in the payload
Treat sampling rate as an analytical decision
Never compare across generations without checking comparability
Keep the raw payload alongside the parsed form
On-device averaging is the quiet decision that removes your best signal.
Trust
Telemetry collects more than anybody apecified
Privacy
- Log content reviewed for what it actually contains rather than what the specification intended
- Patient-associated data handled to the obligations your counsel defines, covered on our privacy page
- Derived inference considered, since usage timing and configuration can reveal more than the fields suggest
- Data residency addressed per market, since a global fleet reports into several jurisdictions
Security
- Telemetry treated as untrusted input on arrival, since the transport is outside your control
- Device identity and credential lifecycle, covered on our identity and device security pages
- Access to raw telemetry scoped by purpose, since service and commercial use are different grants
- Export and bulk access monitored, as the largest disclosure surface on a telemetry platform
Regulatory
- Engineering controls capable of supporting the frameworks that apply, which may include FDA regulation, IEC 62304, IEC 81001-5-1 and ISO 13485
- Applicability, classification and validation strategy determined by your quality and regulatory functions rather than by us
- Where a telemetry-derived value informs a clinical decision, the boundary assessed rather than assumed
- Schema change treated as a device software change where the firmware is in scope
Data governance
- Field definitions versioned, since meaning changes between generations and nothing announces it
- Retention aligned to the obligation and to future questions, covered on our device data engineering page
- Derived metrics documented with their calculation, so a figure can be explained when challenged
- Comparability across generations stated in the data rather than left to the analyst
Read a year of your own diagnostic logs before deciding they contain nothing sensitive.
Quality
Missing telemetry is not random and treating it as random is the error
Reporting completeness per device
Whether gaps correlate with outcomes
Schema version distribution across the fleet
Field population rates
Clock drift and ordering integrity
Cost per device per year
Report coverage with every analysis
So a conclusion from seventy percent of the fleet is never read as a fleet conclusion.
Investigate the gaps rather than excluding them
The missing records are disproportionately the interesting ones.
Version derived metrics
Since a changed calculation restates history across every report consuming it.
Tier storage by access pattern
Covered on our Fabric page, and the largest cost lever in a telemetry platform.
Outcomes
Questions you can answer, and an honest list of those you cannot
| Category | What We Measure | Why It Matters |
|---|---|---|
| Defend Every Number Behind One Metric | Which devices are included and excluded, the observation period, coverage completeness, what qualifies as a fault, whether the definition changed across firmware, whether duplicates are removed, whether delayed events land in the right period, whether exposure is available, whether generations are comparable, and whether another team would calculate the same result | If these cannot be answered the metric is a number rather than a measurement. |
| Questions Answerable | Business questions the current telemetry can honestly answer | The actual capability, as distinct from the data volume. |
| Blocked Questions and Causes | What cannot be answered and whether the cause is schema, resolution or retention | The specification for the next firmware revision. |
| Gap Correlation | Whether missing telemetry correlates with outcomes | If it does, every existing reliability figure is optimistic. |
| Schema Documentation | Fields with recorded meaning, units and applicable generations | A field nobody can explain is one somebody will misuse. |
| Analyst Involvement in Design | Whether analytics reviewed the next generation schema | The only intervention that improves future capability. |
Honest Expectation Setting
Transform medical device telemetry into actionable intelligence
Start with the clinical workflow, not the ambient AI platform.
Bring us a specialty or clinical setting where clinicians are spending too much time creating notes. We will assess where ambient documentation fits, what must remain clinician controlled, how it should integrate with your EHR, and how to measure whether it is actually reducing burden.
- AI Agents and Workflow Automation
- Voice and Conversational AI
- Document AI and Intelligent Processing
- Generative AI and Enterprise Copilots
- AI Strategy and Governance
- HCC and Risk Adjustment Analytics
Security & Compliance